ACM20 Series
Four-Function AC Power Meters
Performance/Functional Speci?cations
Typical at TA=+ 25oC, 120Vac @ 60Hz, unless otherwise noted
Measurement Limits
AC Voltage
Min.
85.0
Typ.
-
Max.
264.0
Units
Volts
ORDERING INFORMATION
AC Current, 10A models ?
AC Current, 32A models ?
AC Current, 100A models ?
Active Power: 10A models
Active Power: 32A models
Active Power: 100A models
Frequency
0.00
0.00
0.0
0
0
0
47.0
-
-
-
-
-
-
-
9.999
32.00
100.0
999.9
9999
26.4
63.0
Amperes
Amperes
Amperes
Watts
Watts
kW
Hz
ACM20-2-AC1-R-C
ACM20-5-AC1-R-C
ACM20-4-AC1-R-C
ACM20-2-AC1-R-F-C
ACM20-5-AC1-R-F-C
ACM20-4-AC1-R-F-C
10A, 85-264Vac Supply (Power Factor Reading)
32A, 85-264Vac Supply (Power Factor Reading)
100A, 85-264Vac Supply (Power Factor Reading)
10A, 85-264Vac Supply (Frequency Reading)
32A, 85-264Vac Supply (Frequency Reading)
100A, 85-264Vac Supply (Frequency Reading)
Power Factor
Overcurrent Rating ?
.00
1.00 -
1.5 x rated full-scale current
-
TECHNICAL NOTES
Performance
IMPORTANT! To ensure safe and reliable operation, ACM20 power
Sampling Rate
Voltage Accuracy ?
Current Accuracy ?
Power Accuracy ?
Frequency Accuracy ?
Power Factor Accuracy
2-3 samples / sec
±1%
±1%
±2%
±0.1
±3%
Hz
!
meters must be installed and serviced by quali?ed technical person-
nel. Contact Murata Power Solutions if there is any doubt regarding
their installation or operation.
1. Measurement Type: ACM20 series multifunction AC power meters
employ a precision energy metering integrated circuit and a low-
power microcontroller to measure and display the rms voltage and
current, active (real) power, power factor (or line frequency on ‘–F’
Measurement Bandwidth
Temperature Drift (0 to 60oC)
140Hz (Voltage), 14kHz (Current)
0.5 Counts/oC
suf?x models) of ac mains supplies from 47-63Hz. Please note,
ACM20 power meters use the voltage present at their TB1 terminal
Zero-Current Reading (within 2 sec.)
Zero-Power Reading (within 2 sec.)
UL/IEC61010-1
0.00
0
Measurement category II
Amps
Watts
block and the secondary current of their built-in current transformer
L1 to calculate and then display VOLTS, AMPS, WATTS, power factor
(PF), or line frequency on ‘-F’ HERTZ models.
Supply Voltage (TB1) (Measurement Category II)
While the ACM20 displays the rms value of line voltage and line
All Models – 47-63 Hz
Supply Current ?
All Models
85
35
120
50
264
110
Vac
mA
current, the VOLTS reading has an upper limit of 140Hz (-3db point),
which means rectangular-shaped voltage waveforms, and waveforms
with sharp transitions, will read lower than their true-rms value. For
example, a square wave line voltage will read approximately 1-2%
Power Supply Terminal Block
lower, a triangle wave will read 3% lower, and a modi?ed sine wave
Wire Size
Insulation Strip Length
Screw Tightening Torque
Rated Voltage
Display
Display Type and Size
Overrange Indication
Decimal Point Selection
Physical/Environmental
16-22AWG, solid or stranded
6.4mm (0.250 in)
0.4Nm (3.6 lb-in)
300Vac
4 Digit LED, 9.14mm (0.36in) high
Flashing ‘9999’ Watts ?
Automatically Set
will read 18% lower. The oscillograms on page seven illustrate typical
ACM20 VOLTS readings when powered from four ac waveforms.
The 140Hz bandwidth limit does not apply to the WATTS reading nor
to the AMPS reading. The circuitry used for these two measurements
has an upper bandwidth of 14kHz. ACM20 power meters are mains
operated devices designed to measure ac currents and voltages,
within the speci?ed limits previously noted. DC currents and voltages
will not be measured accurately.
2. Basic Operation : Upon application of ac power to TB1, the unit will
Operating Temperature
Storage Temperature
Humidity (non-condensing)
0
–40
0
+60
+75
85
°C
°C
%
?rst perform a self-test routine and then continuously display ac volts
with the VOLTS LED annunciator illuminated. The display will remain
in the VOLTS mode as long as the front panel ‘SEL’ button is not
touched.
Dimensions
Weight: 32A models
Weight: 100A models
Hex Nut Tightening Torque
See mechanical speci?cations
1.3oz (37.9g)
1.5oz (43.5g)
0.14 N-m (20 ozf-in)
After the unit powers up to normal operation in the VOLTS reading
mode, momentarily (approximately one second) touching the ‘SEL’
button on the unit’s front panel three times in succession will cycle
the display to AMPS, WATTS, and end at PF (or HERTZ for ‘–F’ mod-
? Speci?ed full-scale currents are those passing through the power meter’s built-in current
transformer’s primary load-circuit.
? The overcurrent rating of 1.5 x the rated full-scale current is a continuous rating and applies
to the current passing through the built in current transformer. Accuracy is guaranteed up to
the rated current.
? ACM20 Power Meters are calibrated with near full-scale 60Hz sine-wave inputs.
? All speci?ed maximum supply currents are steady state; larger surge currents can occur at
initial application of line power.
? Applies to 10A and 32A models only.
els). Momentarily touching ‘SEL’ a fourth time will return the display
back to the VOLTS reading mode.
Holding the ‘SEL’ button down for 3 seconds will place the unit in a
continuous auto-cycling mode, and the display will repetitively scroll
through all four measurements, with each measurement remaining
displayed for 3 seconds.
www.murata-ps.com/support
MPM_ACM20 Series.B03 Page 2 of 6
相关PDF资料
ACM3P-4-AC1-R-C AMMETER LED 85-264VAC 100A RED
AD5721R3 SWITCH ROLLER LEVER ASSMBLY
ADA3721R8 SWITCH ROLLER LEVER ASSMBLY
ADD1721R21 SWITCH ROLLER LEVER ASSMBLY
ADH3721R2 SWITCH ROLLER LEVER ASSMBLY
ADT3723R SWITCH ROLLER LEVER ASSMBLY
AE101SD1AQ04 SW TOGGLE SPDT 5AMP PCB
AE211MD1CB04 SWITCH TOGGLE SP3T 0.4VA T/H
相关代理商/技术参数
ACM20-5-AC1-B-C 功能描述:Multifunction Meter (Current, Voltage, Wattage) LED - Blue Characters Display Panel Mount - Surface 制造商:murata power solutions inc. 系列:ACM20 零件状态:有效 类型:万用表(电流,电压,瓦特) 测量范围:0 ~ 100A 显示类型:LED - 蓝色字符 每行字符数:4 显示字符 - ?高度:0.360"(9.14mm) 输出类型:- 电压 - 电源:85 ~ 264VAC 面板开口尺寸:矩形 - 36.22mm x 22.10mm 安装类型:面板安装 - 表面 端子类型:螺丝端子 侵入防护:- 特性:内置电流互感器(初级) 工作温度:0°C ~ 60°C 重量:0.096 磅(43.54g) 标准包装:12
ACM20-5-AC1-B-F-C 功能描述:Multifunction Meter (Current, Voltage, Wattage, Frequency) LED - Blue Characters Display Panel Mount - Surface 制造商:murata power solutions inc. 系列:ACM20 零件状态:有效 类型:万用表(电流,电压,瓦特,频率) 测量范围:0 ~ 100A 显示类型:LED - 蓝色字符 每行字符数:4 显示字符 - ?高度:0.360"(9.14mm) 输出类型:- 电压 - 电源:85 ~ 264VAC 面板开口尺寸:矩形 - 36.22mm x 22.10mm 安装类型:面板安装 - 表面 端子类型:螺丝端子 侵入防护:- 特性:内置电流互感器(初级) 工作温度:0°C ~ 60°C 重量:0.096 磅(43.54g) 标准包装:12
ACM20-5-AC1-G-C 制造商:Murata Power Solutions 功能描述:AC POWR METER-30A, POWR FACTR
ACM20-5-AC1-G-F-C 功能描述:MULTI METER 0-32A LED PANEL MT 制造商:murata power solutions inc. 系列:ACM20 零件状态:在售 类型:万用表(电流,电压,瓦特,频率) 测量范围:0 ~ 32A 显示类型:LED - 绿色字符 每行字符数:4 显示字符 - ?高度:0.360"(9.14mm) 输出类型:- 电压 - 电源:85 ~ 264VAC 面板开口尺寸:矩形 - 36.22mm x 22.10mm 安装类型:面板安装 - 表面 端子类型:螺丝端子 侵入防护:- 特性:内置电流互感器(初级) 工作温度:0°C ~ 60°C 标准包装:12
ACM20-5-AC1-R-C 功能描述:数字面板表 30A 85-264Vac Supply Power Factor Reading RoHS:否 制造商:Murata Power Solutions 设备类型:AC Voltmeters 显示器类型:LED, 3 Digit, Red 工作电源电压:85 VAC to 264 VAC 工作电源电流:50 mArms 输入电流:50 mA 输入频率: 输入电压:120 VAC 系列:DMS-20PC-1-LM
ACM20-5-AC1-R-F-C 功能描述:数字面板表 30A 85-264Vac Supply Frequency Reading RoHS:否 制造商:Murata Power Solutions 设备类型:AC Voltmeters 显示器类型:LED, 3 Digit, Red 工作电源电压:85 VAC to 264 VAC 工作电源电流:50 mArms 输入电流:50 mA 输入频率: 输入电压:120 VAC 系列:DMS-20PC-1-LM
ACM21 制造商:ABRACON 制造商全称:Abracon Corporation 功能描述:SMD COMMON MODE CHOKE
ACM-21-121M-T 功能描述:2 Line Common Mode Choke Surface Mount 120 Ohm @ 100MHz 370mA DCR 300 mOhm 制造商:abracon llc 系列:ACM-21 包装:剪切带(CT) 零件状态:有效 滤波器类型:信号线 线路数:2 不同频率时的阻抗:120 欧姆 @ 100MHz 电感 @ 频率:- 额定电流(最大):370mA 直流电阻(DCR)(最大):300 毫欧 额定电压 - DC:50V 额定电压 - AC:- 工作温度:-40°C ~ 85°C 等级:- 认可:- 特性:- 安装类型:表面贴装 大小/尺寸:0.079" 长 x 0.047" 宽(2.00mm x 1.20mm) 高度(最大值):0.055"(1.40mm) 封装/外壳:水平式,4 PC 板 标准包装:1